Upgrading The Power Monitor Software - HP 12500 Configuration Manual

Routing switch series
Table of Contents

Advertisement

Step
1.
Enter system view.
Set the interface card in
2.
offline state.
3.
Return to to user view.
4.
Upgrade the power software
on the isolated card.

Upgrading the power monitor software

Typically, the power monitor software is automatically upgraded when the startup software images are
upgraded. If the auto-upgrade fails, use the pmu update command to upgrade it.
This task does no apply to the PSE9000 power module. To identify the power module model, use the
display power-supply command (see "Device management commands").
To avoid power monitor software upgrading failures, follow these guidelines:
The upgrade file must be saved on the switch that holds the power monitoring module to be
upgraded.
In an IRF fabric, save the upgrade file on the active MPU that is in the same chassis as the power
monitoring module.
Do not perform any of the following operations during the upgrade:
Perform an active and standby switchover.
Execute the power-supply off command.
Power off the device.
Reboot or swap the active MPU.
To upgrade the software of a power monitoring module, perform one of the following tasks in user view:
Task
Upgrade the power monitor software (in standalone mode).
Upgrade the power monitor software (in IRF mode).
Command
system-view
In standalone mode:
board-offline slot slot-number
In IRF mode:
board-offline chassis
chassis-number slot slot-number
quit
In standalone mode:
power-logic update [ file
filename ] slot slot-id
In IRF mode:
power-logic update [ file
filename ] chassis chassis-id
slot slot-id
Command
pmu update [ file filename ] pmu-id
pmu update [ file filename ] chassis
chassis-number pmu-id
106
Remarks
N/A
In offline state, a card cannot
forward traffic.
N/A
The command is not available for
MPUs.

Advertisement

Table of Contents
loading