Upgrading Or Repairing The Power Software On An Interface Card - HP 12500 Configuration Manual

Routing switch series
Table of Contents

Advertisement

If you install an interface card during a CPLD upgrade, the system can supply power to the card only after
the upgrade is complete.
To upgrade a CPLD on an interface card or MPU:
Step
1.
Set the interface card in
offline state.
2.
Upgrade a CPLD on an
interface card or MPU
through the MBUS daughter
card.
Upgrading or repairing the power software on an
interface card
Upgrade or repair the power software on an interface card if the card is not properly powered.
To ensure a successful upgrade, follow these guidelines:
In an IRF fabric, the upgrade file must be saved on the active MPU that is in the same chassis as the
card you are working with.
Do not perform any of the following operations during the upgrade:
Perform an active and standby switchover.
Execute the power-supply off command.
Power off the device.
Reboot or swap the active MPU or the card that is being upgraded.
If the system instructs you to choose a card model during the upgrade, use the card model on the
card panel as a reference to make the correct choice. If you fail to enter a choice within 30 seconds
or fail to choose the correct model within five attempts, the upgrade fails.
When the upgrade is complete, the card automatically reboots to run the new software.
If you install a card during a power software upgrade, the system can supply power to the card only after
the upgrade is complete.
To upgrade the power software on an interface card:
Command
a.
Enter system view.
system-view
b.
Isolate the interface card.
In standalone mode:
board-offline slot
slot-number
In IRF mode:
board-offline chassis
chassis-number slot
slot-number
c.
Return to user view.
quit
In standalone mode:
logic update [ file filename ]
slot slot-number logicid logicid
In IRF mode:
logic update [ file filename ]
chassis chassis-number slot
slot-number logicid logicid
105
Remarks
Skip this step if you are upgrading
a CPLD for an MPU.
In offline state, an interface card
cannot forward traffic.
The logicid argument specifies the
CPLD type:
0—Card (interface card or
MPU) CPLD.
1—OAM module CPLD on an
MPU, or CPU CPLD on an
interface card.

Advertisement

Table of Contents
loading

Table of Contents