Nortel Circuit Card 311 Reference page 468

Circuit card
Table of Contents

Advertisement

468 NT7D16 Data Access card
Table 183
Allowable S registers
Range
S register
S0
0–255
S1
0–255
S2
0–127
0–127
S3
S4
0–127
S5
0–32,
127
2–255
S6
S7
1–255
0–30
S8
1–255
S9
S10
1–255
S11
50–255
20–255
S12
You can view any of the S registers by issuing the following display
command. Any S register can be specified through the ATS command,
and the system displays the current setting for that parameter. More than
one S register can be viewed by listing the desired registers on the same
command line.
One registerTwo registers
ATS8?
20
OK
To change any S register range, except S1, use the following change
command. The new parameters remain in effect until another change
command is given or the Hayes Reset modem command (Z) is issued. If
the DAC is powered up, the parameters are reset to the defaults.
ATS8 = 15
Copyright © 2003-2008, Nortel Networks
.
Range units
Supported
Rings
Yes
Rings
Yes
ASCII
Yes
ASCII
Yes
ASCII
Yes
ASCII
Yes
Seconds
No
Seconds
Yes
Seconds
Yes
0.1 second
No
0.1 second
No
Milliseconds
No
20 millisec
Yes
onds
ATS8?
002
006
OK
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Description
Number of rings to answer a system call (0
= manual answer)
Ring count for the current inbound system
call
Off-line escape sequence character
Input/output line terminating character
New line character for the output line
Backspace character for input/output lines
Wait time before blind dialing
Timeout timer for far end answering
Duration for the dial pause character
Carrier detect response time
Delay time between loss of carrier and call
release
Touch tone spacing
Guard time for the escape sequence
S9

Advertisement

Table of Contents
loading

This manual is also suitable for:

1000 con?guration guide