Cable length
26 AWG
1411 m (4600 ft) 2.5
1694 m (5600 ft) 3
2541 m (8300 ft) 4.5
15
8469 m (27800
ft)
The loss plan for the NT1R20 OPS Analog Line Card determines
port-to-port loss for connections between an OPS analog line card unit
(port) and other ports.
The transmission properties of each line unit are characterized by the OPS
or ONS class-of-service assigned in the analog 500/2500-type telephone
administration program LD 10.
The loss plan for the OPS analog line card determines port-to-port loss
for connections between an OPS analog line card unit (port) and other
Meridian 1 PE or IPE ports.
The transmission properties of each line unit are characterized by the
OPS or ONS class-of-service assigned in the Single-line Telephone
Administration program (LD10).
Electrical specifications
This section lists the electrical characteristics of the NT1R20 OPS analog
line card.
The signaling and control portion of the card provides circuits that establish,
supervise, and take down call connections. These circuits work with the
system CPU to operate the line interface circuits during calls. The circuits
receive outgoing call signaling messages from the CPU and return incoming
call status information over the DS-30X network loop.
Signaling and control—This portion of the card provides circuits that
establish, supervise, and take down call connections. These circuits work
with the system CPU to operate line interface circuits during calls. The
circuits receive outgoing call signaling messages from the CPU and return
incoming call status information over the DS-30X network loop.
Copyright © 2003-2008, Nortel Networks
.
Cable loop loss (dB)
(non-loaded at 1kHz)
24 AWG
22 AWG
2
1.6
2.4
1.9
3.7
2.8
12.2
9.4
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Electrical specifications 135
Cable loop resistance (ohms)
26 AWG
24 AWG
385.6
240.3
462.8
288.3
694.2
432.5
2313.9
1441.7
22 AWG
150
180
270
900