914 NTAK20 Clock Controller daughterboard
Specifications
Tuning Range (minimum)
Input Voltage Range
EIA/CCITT compliance
The clock controller complies with 1.5 Mb EIA Stratum 3ND, 2.0 Mb CCITT
or 2.56 Mb basic rate. The differences between these requirements mainly
affect PLL pull in range. Stratum 4 conforms to international markets (2.0
Mb) while Stratum 3 conforms to North American markets (1.5 Mb).
The clock controller complies with 1.5 Mb EIA Stratum 3ND, 2.0 Mb CCITT
or 2.56 basic rate. The differences between these requirements mainly
affect PLL pull in range. Stratum 4 conforms to international markets
(2.0Mb) while stratum 3 conforms to North American market. (1.5 Mb).
The clock controller complies with 1.5 Mb EIA Stratum 3ND, 2.0 Mb CCITT
or 2.56 Mb basic rate. The differences between these requirements mainly
affect PLL pull in range. Stratum 4 conforms to international markets (2.0
Mb) while Stratum 3 conforms to North American markets (1.5 Mb).
Monitoring references
The primary and secondary synchronization references are continuously
monitored in order to provide autorecovery.
The primary and secondary synchronization references are continuously
monitored in order to provide autorecovery.
The primary and secondary synchronization references are continuously
monitored in order to provide autorecovery.
Reference switchover
Switchover occurs in the case of reference degradation or loss of signal.
When performance of the reference degrades to a point where the system
clock is no longer allowed to follow the timing signal, then the reference is
out of specification. If the reference is out of specification and the other
reference is still within specification, an automatic switchover is initiated
without software intervention. If both references are out of specification, the
clock controller provides holdover.
Switchover may occur in the case of reference degradation or loss of signal.
When performance of the reference degrades to a point where the system
clock is no longer allowed to follow the timing signal, then the reference
is out of specification. If the reference being used is out of specification
Copyright © 2003-2008, Nortel Networks
.
CCITT
±60 ppm min.
±90 ppm max.
0 to 10 volts, 5V center
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
EIA
±10 ppm min.
±15 ppm max.
0 to 10 volts, 5V center