Qpc441 3-Port Extender Cards - Nortel Circuit Card 311 Reference

Circuit card
Table of Contents

Advertisement

106 Option settings
S1 and S2—E33
Note: Possible jumper locations for vintage A (for different styles/series). These cards can only be
used in the option A setting:
J3—H5 or E11
J4—H17 or E7
S1 and S2—E33
Note: Connectors and loop relations:
Even loop: J1 faceplate connector, jumper at J4 or S1
Odd loop: J2 faceplate connector, jumper at J3 or S2

QPC441 3-Port Extender cards

For CS 1000M SG and MG systems, QPC441 vintage F or later must be
used in all modules.
Table 44
QPC441 3PE card installed in the NT4N41CP PII Core Net modules
Jumper Settings: Set Jumper RN27 at E35 to "A".
Switch Settings
Module
NT4N41 CP Core/Net modules only
Core/Net 0
(Shelf 0)
Core/Net 1
(Shelf 1)
Copyright © 2003-2008, Nortel Networks
.
D20 switch position
1
Group 0
off
Group 1
off
Group 2
off
Group 3
off
Group 4
off
Group 5
off
Group 6
off
Group 7
off
Group 0
off
Group 1
off
Group 2
off
Group 3
off
Group 4
off
Group 5
off
Group 6
off
Group 7
off
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
2
3
4
on
on
off
on
on
off
on
on
off
on
on
off
on
on
off
on
on
off
on
on
off
on
on
off
on
on
off
on
on
off
on
on
off
on
on
off
on
on
off
on
on
off
on
on
off
on
on
off
5
6
7
on
on
on
on
on
off
on
on
off
on
off
off
on
on
off
on
off
off
on
off
off
off
off
off
on
on
on
on
on
off
on
on
off
on
off
off
on
on
off
on
off
off
on
off
off
off
off
off
8
on
on
on
on
on
on
on
on
off
off
off
off
off
off
off
off

Advertisement

Table of Contents
loading

This manual is also suitable for:

1000 con?guration guide

Table of Contents