Nortel Circuit Card 311 Reference page 649

Circuit card
Table of Contents

Advertisement

See
from far-end PBX" (page 650)
trunk call connection sequence - incoming call from far-end PBX" (page
651).
When the universal trunk card is seized by the far-end on an incoming call,
a low-resistance loop is placed across the tip and ring leads. Addressing
is then sent by the far-end in the form of battery-ground or loop pulses, or
DTMF tones. The trunk is released at the far-end when the loop is opened.
When the near-end detects an open loop, it returns to a normal state.
See
from far-end PBX" (page 654)
trunk call connection sequence - incoming call from far-end PBX" (page
656).
When the NT8D14 Universal Trunk Card is seized by the far-end on an
incoming call, a low-resistance loop is placed across the tip and ring leads.
Addressing is then sent by the far-end in the form of battery-ground or loop
pulses, or DTMF tones. The trunk is released at the far-end when the loop
is opened. When the near-end detects an open loop, it returns to a normal
state. See
call from far-end PBX" (page 655)
trunk call states - incoming call from far-end PBX" (page
When the Universal Trunk is seized by the far end on an incoming call, a
low resistance loop is placed across the tip and ring leads. Dial pulses are
sent by the far end by interrupting the loop current. The trunk is released
at the far end when the loop is opened. When it detects an open loop, the
near end reverts to a normal state.
Outgoing calls
When seized as a dial-selected outgoing trunk, the near-end places the
battery on the tip and ground on the ring. This alerts the far-end of the
seizure. The far-end responds with a low resistance across the tip and
ring leads.
See
far-end PBX" (page 652)
call connection sequence - outgoing call to far-end PBX" (page
Copyright © 2003-2008, Nortel Networks
.
Figure 198 "Two-way, loop OAID, TIE trunk call states - incoming call
Figure 202 "Two-way, loop OAID, TIE trunk call states - incoming call
Figure 203 "Two-way, loop OAID, tie trunk call states - incoming
Figure 200 "Two-way, loop OAID, TIE trunk call states - outgoing call to
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
and
Figure 199 "Two-way, loop OAID, TIE
and
Figure 204 "Two-way, loop OAID, TIE
and
Figure 207 "Two-way, loop OAID, tie
and
Figure 201 "Two-way, loop OAID, TIE trunk
Operation 649
659).
653).

Advertisement

Table of Contents
loading

This manual is also suitable for:

1000 con?guration guide

Table of Contents