Operation - Nortel Circuit Card 311 Reference

Circuit card
Table of Contents

Advertisement

138 NT1R20 Off-Premise Station Analog Line card
Table 66
OPS analog line card - ringer limitations
ONS Loop Range
0–10 ohms
> 10–460 ohms
0 – 10 ohms
> 10 – 900 ohms
> 900 – 2300 ohms
The OPS line card supports up to three NE-C4A (3 REN) ringers on each
line for either ONS or OPS applications. See
card - ringer limitations" (page
Environmental specifications
Table 67 "OPS analog line card - environmental specifications" (page
138)
card.Table 67 "OPS analog line card - environmental specifications" (page
138)
Table 67
OPS analog line card - environmental specifications
Parameter
Operating temperature
Operating humidity
Storage temperature

Operation

The applications, features, and signaling arrangements for each unit on the
NT1R20 OPS analog line card are assigned through LD 10 and/or jumper
strap settings on the card.
The operation of each unit is configured in software and implemented in the
card through software download messages. When the NT1R20 OPS analog
line card unit is idle, it provides a ground on the tip lead and –48 V dc on
the ring lead. The on-hook telephone presents a high impedance toward
the line interface unit on the card.
The applications, features, and signaling arrangements for each unit on
the OPS analog line card are assigned through the Single-line Telephone
Administration program (LD10) and/or jumper strap settings on the card.
Copyright © 2003-2008, Nortel Networks
.
shows the environmental specifications of the OPS analog line
shows the environmental specifications of the card.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Maximum Number of
Ringers (REN)
3
2
3
2
1
Table 66 "OPS analog line
138).
Specifications
0 to +60 C (+32 to +140 F), ambient
5 to 95% RH (non-condensing)
–40 to +70 C (–40 to +158 F)