Nortel Circuit Card 311 Reference page 685

Circuit card
Table of Contents

Advertisement

Table 245
Insertion Loss from IPE Ports to IPE Ports (measured in dB)
The transmission properties of each trunk are characterized by the
class-of-service (COS) you assign in the Trunk Data Block (LD 14).
Transmission properties may be via net loss (VNL) or non via net loss
(non-VNL).
Non-VNL trunks are assigned either a Transmission Compensated (TRC) or
Non-Transmission Compensated (NTC) class-of-service to ensure stability
and minimize echo when connecting to long-haul trunks, such as Tie trunks.
The class-of-service determines the operation of the switchable PADs
contained in each unit. They are assigned as follows:
Table 246 "Insertion Loss from IPE Ports to IPE Ports (measured in dB)"
(page 686)
connections between the Universal Trunk Card (UTC) and any other
Intelligent Peripheral Equipment (IPE) or Peripheral Equipment (PE) unit,
denoted as Port B
Copyright © 2003-2008, Nortel Networks
.
Transmission Compensated
— used for a two-wire non-VNL trunk facility with a loss of greater than
2 dB for which impedance compensation is provided
— or used for a four-wire non-VNL facility
Non-Transmission Compensated
— used for a two-wire non-VNL trunk facility with a loss of less than 2 dB
— or used when impedance compensation is not provided
shows PAD settings and the resulting port-to-port loss for
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Electrical specifications 685