STP(ST')
ST2P(ST")
ST3P(ST")
XMFR receiver specifications
Table 334 "XMFR receiver specifications" (page 845)
requirements for the NTAG26 circuit card.
Table 334
XMFR receiver specifications
Coding:
Input sensitivity:
Frequency sensitivity:
Amplitude Twist:
Signal Duration:
KP Signal Duration:
Signal Interruption Bridge:
Time Shift between 2 frequencies:
(Envelop for start/stop)
Coincidence between 2 frequencies:
Intersignal Pause:
Maximum Dialling Speed:
Noise Rejection:
Error Rate in White Noise
Copyright © 2003-2008, Nortel Networks
.
Digit
9
0
KP
ST
Mu-Law
must accept: 0 to -25 dBmO
must reject: -35 to dBmO
must accept: f +/- (1.5% + 5Hz)
must accept: difference of 6dB between frequencies
must accept: > 30 ms
must reject: < 10 ms
must accept: > 55 ms
may accept: > 30 ms
must reject: < 10 ms
must ignore: < 10 ms
must accept: < 4 ms
must reject: < 10 ms
must accept: > 25 ms
must accept: 10 signals per second
Better than: < 1/2500 calls
Test:
10 digit calls
nominal frequency @ -23 dBmO
ON/OFF = 50 ms/50ms
KP duration 100 ms
SNR = -20 dB
all digits
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
MF signaling 845
Backward direction
DOD-Tx, DID-Rx
1100 Hz + 1500 Hz
1300 Hz + 1500 Hz
1100 Hz + 1700 Hz
1500 Hz + 1700 Hz
900 Hz + 1700 Hz
1300 Hz + 1700 Hz
700 Hz + 1700 Hz
provides the operating