3.21.7 AGING Test (5: AGING TEST)
Not used.
3.21.8 FACULTY (function) Test (6: FACULTY TEST)
A press on '6' on the keypad from the TEST MODE menu selects the FACULTY test. A
press on the keypad (1 through 7, 9, #) during the test will bring up the following menu:
Keypad
Item
1
G3 Signal Transmission Test
2
not used
3
Sensor Test
4
ADF Test
5
not used
6
Speaker Test
7
Control Panel Test
9
Live Connection Reception Test
#
ESS Test
G3 Signal Transmission Test (6-1: G3 4800 bps Tx)
A press on '1' on the keypad on the FACULTY TEST menu selects the G3 transmission
test. In this test, a G3 signal is transmitted using the telephone line terminal and the speaker
at 4800 bps.
Sensor Test (6-3: SENSOR)
This mode is used to check the state of a specific sensor of the machine on the LCD. A
press on '3' on the keypad from the FACULTY TEST menu selects the sensor test. The LCD
indication changes as the sensor goes ON and OFF.
COPYRIGHT © 2002 CANON INC.
2000 2000 2000 2000
CANON SmartBase PC1210D/1230D/1270D REV. 1 MAR. 2002
CHAPTER 2 USING THE MACHINE
Description
Transmits a G3 signal at 4800 bps to the telephone
line and the speaker.
Executes an operation test on a specific sensor.
Executes an operation test on the ADF.
Executes an operation test on the speaker.
Executes an operation test on the LCD/LED/control
panel keys.
Executes an operation test on the signal sensor on
the NCU board and the frequency counter.
Executes an operation test on the ESS function.
2-81