SPECIFICATIONS
FaST SYSTEM (OPTION)
Item
Solution pump
Solution flow rate
Detergent pump
Concentrate flow rate
Concentrate to water dilution ratio
Air pump
Air pump flow rate
ec- H2O SYSTEM (OPTION)
Item
Solution pump
Solution flow rate* -- Disk 700 mm
Solution flow rate* -- Disk 800 mm
Solution flow rate* -- Disk 900 mm
Solution flow rate* -- Cylindrical 700 mm
Solution flow rate* -- Cylindrical 800 mm
Solution flow rate* -- Cylindrical 900 mm
* If the optional solution flow rates are required, contact an Authorized Service Center.
GENERAL MACHINE PERFORMANCE
Item
Aisle turnaround width with 700 mm scrub head
Aisle turnaround width with 800 mm scrub head
Aisle turnaround width with 900 mm scrub head
Maximum rated climb and descent angle with empty tanks
Maximum rated climb and descent angle with full tanks
74
Home
Measure
36 Volt DC, 5A, 5,7 LPM (1,5 GPM) open flow,
45 psi bypass setting
0,83 LPM (0,22 GPM)
36 Volt DC
0,9 CC/Minute (0,03 Ounces/Minute)
1:1000
24 Volt DC, 0,6 Maximum Amp draw
8,7 LPM (0,3 CFM) open flow
Measure
36 Volt DC, 5A, 5,7 LPM (1,5 GPM) open flow,
45 psi bypass setting
0,83 L/min / 0,22 gpm (standard)
1,25 L/min / 0,33 gpm (optional)
1,66 L/min / 0,44 gpm (optional)
0,83 L/min / 0,22 gpm (standard)
1,25 L/min / 0,33 gpm (optional)
1,66 L/min / 0,44 gpm (optional)
1,10 L/min / 0,30 gpm (standard)
1,66 L/min / 0,44 gpm (optional)
2,00 L/min / 0,53 gpm (optional)
1,25 L/min / 0,33 gpm (standard)
1,66 L/min / 0,44 gpm (optional)
1,25 L/min / 0,33 gpm (standard)
1,66 L/min / 0,44 gpm (optional)
1,66 L/min / 0,44 gpm (standard)
2,00 L/min / 0,53 gpm (optional)
Find... Go To..
Measure
1.685 mm
1.700 mm
1.715 mm
8_
6_