MAINTENANCE
7. Disconnect the lift arms from the scrub head
by removing the two clevis pins.
8. Mark the location of the actuator tube on the
actuator shaft before disconnecting the
actuator. Disconnect the actuator from the
scrub head by removing the clevis pin.
9. To install the scrub head, connect the lift
arms to the scrub head with the two clevis
pins.
10. Connect the scrub head to the guide with the
clevis pin.
11. Make sure the actuator tube lines up with the
mark made earlier on the actuator shaft. If
not, turn the actuator tube until it does.
Connect the actuator to the scrub head with
the clevis pin.
12. Connect the wire harness.
13. Connect the solution line to the scrub head
tee fitting.
48
Home
Find... Go To..
5680 330459 (9- -02)