Solution Flow Lever; Circuit Breakers - Tennant 5680 Operator's Manual

Hide thumbs Also See for 5680:
Table of Contents

Advertisement

OPERATION

SOLUTION FLOW LEVER

The solution flow lever controls the amount of
solution flow to the floor.
Increase: Push the lever forward.
Decrease: Pull the lever backward.
NOTE: A solenoid valve dispenses the solution to
the scrub head. The valve opens when the
steering handles are rotated forward, and closes
when the steering handles are released in neutral
position.
NOTE: When using the FaST or ec- -H2O system
(option), the solution flow lever is nonfunctional.
The FaST and ec- -H2O system flow rates are
pre- -set. The ec- -H2O module has optional flow
rate settings. If solution flow adjustments are
required, contact an Authorized Service Center.

CIRCUIT BREAKERS

The circuit breakers are resettable electrical circuit
protection devices. They stop the flow of current in
the event of a circuit overload. Once a circuit
breaker is tripped, reset manually by pressing the
reset button after the breaker has cooled down.
If the overload that caused the circuit breaker to
trip is still there, the circuit breaker will continue to
stop current flow until the problem is corrected.
The circuit breakers are located on each side of
the operator console.
The chart shows the circuit breakers and the
electrical components they protect.
Circuit
Breaker
Rating
CB1
10 A
CB2
25 A
CB3
25 A
CB4
30 A
CB5
30 A
CB6
10 A
10 A
14
Home
Circuit Protected
Machine power
Vacuum fan motor
Machine propel
Right brush motor
Left brush motor
FaST (option)
ec- -H2O (option)
Find... Go To..
5680 330459 (10- -08)

Advertisement

Table of Contents
loading

Table of Contents