Direct exhaust as necessary to keep ambient air temperature within operating spec
(see Section 6, Specifications). If the projector is used for extended periods,
particularly in a confined space, routing to the outside of the building may be
required. In all cases, maintain at least 600 CFM at the projector's top exit port:
Lamp (kW)
Follow the installation guidelines provided below, securing all
INSTALLATION:
components in the order that best suits your site and installation requirements.
Do not operate the projector without the Christie
1.
INSTALL DUCT ON PROJECTOR:
Figure 2.23 below. Align either the 6-
inch or 6-foot duct at the projector's
top exit port, twisting to secure "flaps"
over projector pins. Confirm that 1)
there are no obstructions or "kinks"
within the ducting, 2) all air intake
areas of the projector are clear and
exposed, and 3) the vane switch at the
exit duct moves freely.
Table 2.3. Airflow Requirements
Minimum Exhaust Airflow Rate
2.0
600 ft
3
3.0
600 ft
3
4.5
600 ft
3
3
6.0
600 ft
WARNING
Extractor components installed.
See
Figure 2.22. Securing Extractor to
INSTALLATION AND SETUP
/min.
/min.
/min.
/min.
Duct
Roadie 25K User's Manual