If you accidentally touch the quartz body of the lamp with your bare hands, clean the
surface as described in 4.3, Maintenance and Cleaning.
'
STEP 9
Check Leads
Make sure that the anode (+) lead between lamp and igniter is well away from any
projector metal such as the reflector or firewall.
'
STEP 10
Close cooling compartment and lamp door
The projector will not operate unless the louvered door is locked shut.
'
STEP 11
Record the LAMP INSTALLED
With a blue dot label or dry-erase pen, mark the lamp door's LAMP INSTALLED
label to indicate the size of the newly installed lamp — 2.0, 3.0, 4.5, or 6.0 kW. A
supply of blue dot labels is secured inside the front cover of this manual.
Figure 4.2. Secure bulb at cathode (–) and anode (+) connectors
Proper electrical contact prevents
resistance in the lamp connectors.
Leads too close to metal parts will cause arcing during
starting pulse. This is a SAFETY HAZARD,
and the lamp may not ignite.
IMPORTANT
WARNING
Roadie 25K User's Manual
MAINTENANCE
4-9