■ Server Management Tools Error Messages

The following error messages may appear while executing Server Management Tools. Perform the
corresponding resolution listed in the table. If messages other than the following are displayed, contact
an office listed in the "Contact Information" of "Start Guide".
Message
Write protect error writing drive A.
Abort, Retry, Fail?
Not ready writing drive A.
Abort, Retry, Fail?
ERROR:Fail to create data file.
ERROR:Fail to write 1st CMOS data into data
file. nn
ERROR:Fail to write 2nd CMOS data into data
file. nn
ERROR:Fail to write ESCD data into the data
file. nn
ERROR:Fail to write SEEPROM data into the
data file. nn
ERROR:Fail to open data file.
ERROR:Fail to write 1st CMOS data into system.
nn
ERROR:Fail to write 2nd CMOS data into system
file. nn
ERROR:Fail to write ESCD data into system file.
nn
ERROR:Fail to write SEEPROM data into
system. nn
Other messages
table: List of Server Management Tools Error Messages
The inserted floppy disk is write-protected. Disable the
write-protect, and then press the [R] key.
The floppy disk is not inserted into the floppy disk drive.
Insert the proper floppy disk ("Server Management Tools"
disk), and then press the [R] key.
The following are possible causes. Check the floppy disk
status again.
• The floppy disk is not inserted into the floppy disk drive.
Insert the proper floppy disk, and then retry.
• The floppy disk is write-protected. Disable the write-
protect and retry.
• The floppy disk contains abnormal contents. Create the
"Server Management Tools" disk again. If this occurred
while recovering BIOS information, configure the
information using the BIOS Setup Utility. Then store the
BIOS information.
The file for recovering the BIOS information does not exist
on this floppy disk. Insert the floppy disk on which the BIOS
information was stored, and then retry.
The following are possible causes. Check the floppy disk
status again.
• The floppy disk is not inserted into the floppy disk drive.
Insert the proper floppy disk, and then retry.
• A different model or an unsupported version of BIOS
information. Insert the proper floppy disk, and then retry.
• The floppy disk contains abnormal contents. Create the
"Server Management Tools" disk again. If this occurred
while recovering BIOS information, configure the
information using the BIOS Setup Utility. Then store the
BIOS information.
Contact an office listed in the "Contact Information" of
"Start Guide".
PRIMERGY RX100 S2 User's Guide