This section describes how to install an OfficeServ 7100 cabinet on a table/desktop in a data
rack or on a wall, depending on the installation environment.
2.1 SYSTEM INSTALLATION PROCEDURE
The procedure of system installation is as follows.
1) Install the OfficeServ 7100 cabinet on a table, inside a data rack or on the wall depending
on the installation environment.
2) Connect the ground to the ground lug located in the back of the cabinet.
3) Install the MP10/MP10a card into slot 0 of the cabinet.
4) Install interface cards or UNI cards (with the required daughtercards modules installed on
them) into universal slots (slots 1 or 2) of the cabinet.
5) Connect an external battery with proper capacity if required.
6) Connect AC 110V input power.

2.2 SELECTING INSTALLATION METHOD

The OfficeServ 7100 cabinet can be installed on a table, inside a 19-inch rack or on a wall
depending on the installation environment or customer requirements.

2.3 INSTALLING IN A RACK

2.3.1 Cautions for Installation
Take the following precautions when installing the OfficeServ 7100 cabinet inside a rack:
• The 19-inch rack should be a standard equipment rack.
• When using an enclosed-type rack, check if the rack is properly ventilated. Vents should be
equipped on the side of the rack and fans should be attached to ventilate cool air into the
rack.
Take special caution when using an enclosed-type rack that has vents on top of the rack
since hot air coming out of the vent may enter the intake vent of a system installed above
the rack.
• When using an open rack, do not block the entrance of a port or the OfficeServ 7100 fan.