3.2.1a Setting Switches on MP10
On the MP10 set the switches for the required configuration. The description for the settings
is described below.
• Memory Backup Switch (S1): When set to ON, all system programming is saved in SRAM
even when system is rebooted or powered OFF. This will be saved in SRAM until the Super
Capacitor has been drained of all charge (this charge will last only up to 24 hours with
system power OFF). At that point all programming will be lost. It is recommended that all
programming is saved to the MP10 MMC+/SD card or to a PC using the OfficeServ
Installation Tool application. Turning the switch (S1) OFF will set the system to DEFAULT.
To default the system, keep this switch (S1) in the OFF position for 30 seconds. Switch to
ON position before powering up the system.
Note: The S2 dip switches are set properly by the factory for a 3-digit numbering plan and
the country of USA. These dip switches should be left at default and should never be
changed. If a 4-digit numbering plan is required, the numbering plan should be changed
in the software by using MMC 724.
ON (left)
4 DIGIT STATION NUMBERS
4 DIGIT STATION GROUPS
4 DIGIT TRUNK NUMBERS
Figure 3.2a Switch Setting (MP10)
DIP SWITCH USE (S2)
SW8
SW7
SW6
RESERVED
SW5
COUNTRY SELECT
SW4
COUNTRY SELECT
SW3
COUNTRY SELECT
SW2
COUNTRY SELECT
SW1
3.3
Home Page
OFF (right)
3 DIGIT STATION NUMBERS
3 DIGIT STATION GROUPS
3 DIGIT TRUNK NUMBERS
RESERVED
COUNTRY SELECT
COUNTRY SELECT
COUNTRY SELECT
COUNTRY SELECT