2.8 [1] Configuration
Click the desired cell in the column.
Select the desired cell in the column, and then click Command.
Default
Current status
Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the PBX.
Maintenance Console Location
2.8.5 [1-1] Slot—Port Property - Extension Port
Programming Manual References
2.8.6 [1-1] Slot—Port Property - Extension Port—Connection Command
Feature Manual References
None
Extension Number
Specifies the extension number of the port.
To change the extension number of a wired extension, follow the steps below:
1.
Type the new extension number, then click Apply.
2.
Set the status of the extension port to "OUS", then "INS".
When changing the extension number, make sure that the extension port is not in use. If the extension
number is changed while the port is in use, the new extension number will not come into effect.
Extension numbers of PSs can be a maximum of 4 digits.
Default
For KX-TDA50/KX-TDA100/KX-TDA200:
Starting at 101
For KX-TDA600:
Starting at 1001
(For port 01 of the first extension card that is installed. Extension numbers are preset for subsequent
extensions by adding one to the previous extension number.)
Value Range
Max. 5 digits (consisting of 0–9)
Maintenance Console Location
2.8.5 [1-1] Slot—Port Property - Extension Port
Programming Manual References
2.8.6 [1-1] Slot—Port Property - Extension Port—Connection Command