2.16 [9] Private Network
Network Data Transmission for Centralized Operator Feature—Data
Transmission Counter
Specifies the maximum number of "hops", or transmissions between two PBXs, before a packet of
BLF data is discarded.
Default
8
Value Range
1–63
Maintenance Console Location
2.16.2 [9-2] Network Data Transmission
Programming Manual References
None
Feature Manual References
1.13.15 Private Network Features—NDSS (Network Direct Station Selection)
Network Data Transmission for Centralized Operator Feature—Data
Broadcasting Interval Timer
Specifies the frequency of BLF data transmission. The PBX will send data over the network
periodically according to the interval specified here.
Default
3000 ms
Value Range
100 × n (n=0–30) ms
Maintenance Console Location
2.16.2 [9-2] Network Data Transmission
Programming Manual References
None
Feature Manual References
1.13.15 Private Network Features—NDSS (Network Direct Station Selection)
Network MSW Data Transmission for Centralized VM Feature—Data Re-
transmission : Repeat Counter
Specifies the number of times re-transmission of network message waiting notifications is repeated
before being canceled.