2.8 [1] Configuration
Feature Manual References
1.3.21 CTI (Computer Telephony Integration)
Voice (RTP) UDP Port No. (Server)
Specifies the UDP port used by the IP-EXT card to transmit and receive RTP (Realtime Transfer
Protocol) data. This must be changed if another network application is using the same port.
For voice communications, an IP-EXT16 card uses 64 and an IP-EXT4 card uses 16 contiguous UDP
ports, starting from the port number specified here.
Default
8000
Value Range
1024–65472
Maintenance Console Location
2.8.23 [1-1] Slot—Card Property - IP Extension—Common Settings
Programming Manual References
None
Feature Manual References
1.9.15 IP-PT (IP Proprietary Telephone)
Voice (RTP) UDP Port No. (IP-PT)
Specifies the UDP port used to transmit and receive RTP (Realtime Transfer Protocol) data on the IP-
PT side. This must be changed if another network application is using the same port.
For voice communications, an IP-PT uses 64 (with the IP-EXT16 card) or 16 (with the IP-EXT4 card)
contiguous UDP ports, starting from the port number specified here.
Default
8000
Value Range
1024–65472
Maintenance Console Location
2.8.23 [1-1] Slot—Card Property - IP Extension—Common Settings
Programming Manual References
None
Feature Manual References
1.9.15 IP-PT (IP Proprietary Telephone)