Order Of Installing Extension Blades; Order Of Installing Trunk Blades; 2.1.3.1 Installing Coiu, 4Tliu, Diopu, Or Bri Blades; 2.1.3.2 Installing T1/Pri Blades - NEC UX5000 Hardware Manual

Hide thumbs Also See for UX5000:
Table of Contents

Advertisement

Chapter 2 - Blade Installation and Startup
2.1.2

Order of Installing Extension Blades

The order that the station Blades (ESIU and SLIU) are physically inserted determines
the numbering plan.
For example, with a digital station blade (16ESIU) in slot #1 (ext. 301-316), when 3 additional digital station
blades are installed in the following order, the numbering plan below applies:
After the initial powering up of the system, subsequent powering up or resets will not change the slot
identification. System programming (Program 90-05) must be performed to change the slot identification.
2.1.3

Order of Installing Trunk Blades

2.1.3.1 Installing COIU, 4TLIU, DIOPU, or BRI Blades:

The order in which trunk blades are physically inserted determines the numbering plan.
For example, if four blades are installed in the following order, the numbering plan below would
apply:

2.1.3.2 Installing T1/PRI Blades

The T1/PRI Interface blade uses the first block of 24 consecutive trunks.
For example, if you have an 4COIU blade with a 4COIDB installed for trunks 1-8, the T1/PRI blade
will automatically use trunks 9-32. If you have 4COIU blade with a 4COIDB installed for trunks 1-8
and 17-24, the T1/PRI blade will use trunks 25-48. The T1/PRI blade cannot use trunks 9-16 (even
if available) since they are not part of a consecutive block of 24 trunks.
2 - 2
Order of
Blade Slot #
Install
1
2
3
4
Order of
Blade Slot #
Install
1
5
2
6
3
8
4
7
Ext Numbers
2
301-316
3
317-332
5
333-348
4
349-364
Blade
Line Circuits
4COIU with
1-8
4COIDB
4COIU
9-12
4TLIU
13-16
4TLIU
17-20
Chapter 2