POWER FAILURE TERMINALS

4.15.1

Power Failure (Figure 4-31)

The system allows connection for basic telephone service during a power failure. The power failure operation
occurs during a commercial power failure, and is not affected by blade failure. Power Failure Transfer is
provided by connecting to the COIU blade.
The 4COIU blade provides 2 Power Failure Transfer circuits. The CN3 connector provides connection to 2
analog trunk ports, which are polarity sensitive (tip to tip, ring to ring). The power failure circuits, however,
are not polarity sensitive.
4.15.2

Connector Pin-Outs on COIU Blade for Power Failure Circuits

Chapter 4
When connecting the RJ61 cables to the COIU blade, note the position of the
Power Failure connector. Do not confuse this connector as the trunk connector.
RJ61 Cable Connector - CN3, SLT Interface for Power Failure
12345678
Chapter 4 - Terminals and Optional Equipment
! Important !
Pin No.
1
2
3
4
5
6
7
8
Connection
-
-
Circuit 2 - Tip
Circuit 1 - Ring
Circuit 1 - Tip
Circuit 2 - Ring
-
-
4 - 61