Programming The Ip-Cts Or Enhanced Terminals For The Lock Feature; Feature Activated - NEC UX5000 Hardware Manual

Hide thumbs Also See for UX5000:
Table of Contents

Advertisement

Chapter 4 - Terminals and Optional Equipment
4.17.10

Programming the IP-CTS or Enhanced Terminals for the Lock Feature

The Lock button on the IP-CTS or IP Enhanced terminals will provide a user with the ability to prevent calls on
their terminal while away from their desk. This will prevent all calls from being dialed - including 911 (unless
allowed by changing the terminal's setup (as defined below). A terminal must be defined within programming
to enable the Lock button.
15-05-24 : IP Terminal Basic Data Setup - Lock/Protection Mode
Enable (1) or disable (0) the user of the Lock/protection button for UX5000 IP terminals.
90-49-01 : Button Kit Information of Multi-Line Terminal - Release Protection Mode
If required, release the lock/protection state of a UX5000 IP termina.
90-49-02 : Button Kit Information of Multi-Line Terminal - Initialize Password Protection
If required, initialize the lock/protection password of a UX5000 IP terminal.
In addition to the previous UX5000 programming, the password must be defined for the user within the specific
terminal setup.
With an IP-CTS terminal, you can touch the option on the screen in the steps below instead of pressing the
option numbers.
1.
Press the MENU button.
2.
Press 1 for SETTING, then press 1 for USER SETTING.
3.
Press 4 for CHANGE PASSWORD.
4.
Dial the default/existing password (by default, each terminal's password is: 0000.) then enter the new
password to be used for the terminal and then re-enter the new password to confirm.
5.
Press the OK Soft Key twice, then press the BACK Soft Key until the terminal is back to an idle condition.
4.17.11
Programming the IP Terminal for the 911 Dialing When Lock Feature Activated
The Lock button on the IP terminals will provide a user with the ability to prevent calls on their terminal while
away from their desk. This will prevent all calls from being dialed - including 911. In order to allow anyone to
dial 911 from a locked IP terminal, each terminal must be set up to override the lock function. Each IP terminal
can have up to 3 emergency numbers defined which can be dialed when a terminal is locked. Perform the
following steps on any IP terminal which may be used to dial an emergency number.
1.
Enter the terminal's program mode by pressing HOLD CONF * #.
2.
At the log-in screen, enter the user name (default: ADMIN) and password (default: 6633222) and press
the OK Soft Key.
3.
Press Soft Key 6 for "Application Setting".
4.
Press Soft Key 5 for "Emergency Call".
5.
Press Soft Key 1, 2 or 3 for the emergency number entry.
6.
Dial the emergency number to be allowed (ex: 911).
7.
Press Soft Key 4 for "OK" to complete.
8.
Continue pressing Soft Key 4 to exit (Exit-Exit-Save). The terminal will reset automatically.
4 - 76
Once a locked terminal is used to dial an emergency number, the terminal will be
unlocked until the Lock button is pressed again.