Installing A Did Choke; Did Choke - NEC UX5000 Hardware Manual

Hide thumbs Also See for UX5000:
Table of Contents

Advertisement

Chapter 3 - Installing Extensions and Trunks
S
3-10
ECTION

INSTALLING A DID CHOKE

3.10.1

DID Choke

If your central office has a high level of AC noise or if your site is experiencing excessive hum on the DID lines,
a customer-provided isolation transformer can be installed between the UX5000 and telco blocks to help to
suppress the hum.
DID trunks must be bridged from the telco RJ21X to a line cross-connect (A) block. The choke is installed
between these two blocks.
DID Choke Installation:
1.
Remove the bridging clips on the (A) block and telco block for the DID lines.
2.
From the telco block, solder the Tip lead to the "3" connector on the choke.
3.
From the telco block, take the Ring lead and solder it to the "1" connector on the choke.
4.
From the (A) block, take the Tip 1 lead and solder it to the "4" connector on the choke.
5.
Solder the Ring 1 lead from the (A) block to the "2" connector on the choke.
6.
Reinstall the bridging clips as required.
3 - 12
Chapter 3

Advertisement

Table of Contents
loading

Table of Contents