21. Apply a thin, continuous film of Crankcase Sealant
(PN 2871557) to sump cover mating surface (Item
14) as shown. Do not allow sealant to dry before
assembly.
22. Install the oil sump cover (Item 15) onto the
crankcase.
23. Install the thirteen M6 (Item 16) and three M8 bolts
that retain the oil sump cover (Item 17) to the
crankcase.
9924874 R02 - 2014 RZR XP / XP 4 1000 Service Manual
© Copyright 2013 Polaris Industries Inc.
24. Torque the oil sump cover bolts in sequence to
specification. Repeat the sequence to verify final
torque.
Oil Sump Cover Bolts:
M8 Bolts:
26 ft-lb (35 Nm)
M6 Bolts:
106 in-lb (12 Nm)
25. Reinstall the crankcase drain plug if previously
removed. Torque drain plug to specification.
Crankcase Drain Plug:
12 ft-lbs (16 Nm)