5. Service Tables
5
TX Settings
Overseas Comm
Mode Settings
146
After the line is connected via the external telephone, the
machine can detect silence (no tone) for the time length
specified by this setting.
[30 sec (Default)]
CNG tone detection time ( RX mode : FAX / TEL, FAX / TAD
Only)
CNG Tone
After the line is connected via the external telephone, the
Detection Time
machine can detect a CNG signal for the time length
specified by this setting.
[5 Sec (Default)/ 10 Sec]
Number of CNG cycles to be detected
CNG Cycles
This setting is only effective for FAX/TAD mode.
[1.5 Cycle (Default)/ 2.0 Cycle]
Determines the period when tones from the line are
Tone Sound
monitored.
Monitoring
[No Monitoring/ Up To Phase B (Default)/ All TX Phases]
Pressing the Stop/Clear key can stop the current receiving
operation. Received data is lost.
Stop/Clear key
[Not Functional (Default)/ Functional]
Sets the off-hook detection threshold.
Off-Hook Level
[10V (Default)/ 15V/ 20V/ 25V]
Sets the redial interval when Tx fails.
Redial Interval
[5 Min/ 6 Min]
Sets the number of redials when Tx fails.
Redialings
[2 times/ 3 Times/ 4 Times/ 5 Times]
This sets the machine to ignore a DIS signal sent from the
Overseas Comm
called station once in a sending operation.
Mode
[Off (Default)/ Ignore DIS Once]
If this setting is set to "On", the machine detects the CNG
signal after the line is connected. If it is set to "Off", the
Minimum Time
machine detects the CNG signal as long as the line is
Length
connected.
[100 Ms/ 200 Ms/ 300 Ms/ 400 Ms (Default)]