Flatbed Sub Reg.
Fax Maintenance (G181 doesn't support this.)
RX Level
Modem Settings
TX Level
Cable Equalizer
Training Retries
Protocol Definition
Encoding
T0 Timer
Protocol Definition
Timer
T1 Timer
T4 Timer
Silence Detection
RX Settings
Time
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Adjusts the Flatbed Scan sub-scan magnification. (G181
doesn't support this.)
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Sets the reception level.
[-43 dBm (Default)/ -33 dBm/ -26 dBm
/ -16 dBm]
Sets the transmission level.
[0 dBm/ -1 dBm/ -2 dBm/ -3 dBm/ -4 dBm
/ -5 dBm/ -6 dBm/ -7 dBm/ -8 dBm/ -9 dBm
/ -10 dBm/ -11 dBm/ -12 dBm/ -13 dBm
/ -14 dBm/ -15 dBm]
These selectors are used to improve the pass-band
characteristics of analogue signals on the telephone line.
[0Km (Default)/ 1.8Km/ 3.6Km/ 7.2Km]
This sets the number of training retries to be repeated before
automatic fallback.
[1 Time/ 2 Times (Default)/ 3 Times/ 4 Times]
Sets the compression method for Tx/Rx.
[MMR+MR+MH (Default)/ MR+MH/ MH]
Timeout for response from the called station in automatic
sending mode
[35 Sec/ 45 Sec/ 55 Sec (Default)/ 60 Sec/ 90 Sec/
140 Sec]
Set the time length for the T1 timer.
[40 Sec (Default)/ 50 Sec]
Set the time length for the T4 timer.
[3 Sec (Default/ 4.5 Sec]
Silence (No tone) detection time (Rx mode : FAX/ TAD
Only)
Service Menu (MF Model)
145
5