5. Service Tables
Reset Count
Clear Count
Replace Fuser
Scan Maintenance
Mono Compression
5
Setting
Regist Adjust
Size Adjust
144
Adjusts the vertical registration for the back side in duplex
mode. If the machine settings are reset to the factory
Vert.Dup.Back
defaults, this value does not change.
[-15 to 15 / 0 (Default) / 0.3 mm/step]
Resets counters to factory defaults.
Clears the Scanner and Jam Counters.
Resets the maintenance counter for the fusing unit..
This item appears only when the fusing unit life is almost expired or has expired.
Sets the monochrome compression type for scanning.
MH (Default)/ MR/ MMR
Adjusts the ADF Scan main-scan registration. (G181
doesn't support this.)
ADF Main Reg.
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
Adjusts the ADF Scan sub-scan registration. (G181 doesn't
support this.)
ADF Sub Reg.
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
Adjusts the Flatbed Scan main-scan registration. (G181
doesn't support this.)
Flatbed Main Reg.
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
Adjusts the Flatbed Scan sub-scan registration. (G181
doesn't support this.)
Flatbed Sub Reg.
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
Adjusts the ADF Scan main-scan magnification. (G181
doesn't support this.)
ADF Main Reg.
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Adjusts the ADF Scan sub-scan magnification. (G181
doesn't support this.)
ADF Sub Reg.
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Adjusts the Flatbed Scan main-scan magnification. (G181
Flatbed Main Reg.
doesn't support this.)