DIGITAL-LOGIC AG
EMI / EMC Tests
If all signals are externaly filtered and assembled into a closed metalic case !
EMC emission EN61000-6-2:2001
Conducted disturbance
Radiated disturbance
EMC immunity EN61000-6-2
Electrostatic discharge (ESD)
Radiated RF-Field
Electrical fast transients (Burst)
Surge
Conducted disturbances
Security:
e1:
UL
ETS 301
CE/SEV
Safety
Any information is subject to change without notice.
Specification
EN55022 Class B
EN55022 Class B
EN61000-4-2
Voltage = 4kV contact / 8kV air
Criteria A
EN61000-4-3
Level = 10V/m
Criteria A
EN61000-4-4
Grade 2: DC-Powerlines = 1000V (5/50ns)
Grade 2: AC-Powerlines = 2000V (5/50ns)
Grade 2: Signallines
Criteria B
EN61000-4-5
Grade 2: DC-Powerlines = 1kV, (1.2/50us)
Grade 2: AC-Powerlines = 2kV, (1.2/50us)
Criteria B
EN61000-4-6
Voltage = 10V coupled by case
Criteria A
Not planed
Not planed
Not planed
Yes
AR385-16
15
MSM586SEN/SEV Manual V1.5E
= 500V (5/50ns)