Telemetry:vario - FUTABA 6K Instruction Manual

6-channel digital proportional r/c system
Hide thumbs Also See for 6K:
Table of Contents

Advertisement

VARIO : Display of SBS-01A (Option), and alarm setup
VARIO is a screen which displays / sets up the
variometer information from an optional altitude
sensor.
The variometer of the model which is flying can
be known.
If it becomes higher or lower than the setting an
alarm and/or vibration will ALARM you.
●Select [VARIO] in the TELEMETRY screen and access the
setup screen shown below by press the Jog key.
● " U P " i n d i c a t e s t h e
alarm will start when
t h e v a r i o r e a c h e s
above your set value.
● " D N " i n d i c a t e s t h e
alarm will start when
t h e v a r i o r e a c h e s
below your set value.
● Y o u c a n h e a r t h e
Vario data through an
earphone or headset,
by Activating the Speech
function.
ALARM set : Rise side
1. Move the cursor to the UP:(ALARM) item.
2. Select the ACT mode by press the +-key.
3. Move the cursor to the UP:(LIMIT)[value]item.
4. Ajust the rate by press the +-key.
Initial value: +50(m/s)
Adjustment range: -150~+150(m/s)
(UP:(LIMIT) ≧ DN:(LIMIT))
*When the + - key simultaneous press, the rate is reset to the
initial value.
(To terminate the input and return to the
original state, touch the END key.)
84
*An altitude sensor must be installed in the aircraft.
●Variometer
VARIO
0 m/s
MIN/MAX=
0 /
(ALARM)
(VIB)
UP▶INH
▶OFF
DN▶INH
▶OFF
SPEECH▶ INH
SW▶ NULL
● Switch selection
● Conversion of a display unit is performed by "TLM UNIT" of 
"PARAMETER".
●The maximum and the minimum
when powering ON are shown.
● Maximum and minimum date reset by
pressing the Jog key for 1 second.
0
(LIMIT)
If the following types are selected, the
▶  +50
transmitter will vibrate during the warning.
-50
TYPE 1
TYPE 2
TYPE 3
OFF
OFF
OFF
ON
ON
2 Position
3 Position
ALARM set : Low side
1. Move the cursor to the DN:(ALARM) item.
2. Select the ACT mode by press the +-key.
3. Move the cursor to the UP:(LIMIT)[value]item.
4. Ajust the rate by press the +-key.
Initial value: -50(m/s)
Adjustment range: -150~+150(m/s)
(UP:(LIMIT) ≧ DN:(LIMIT))
*When the + - key simultaneous press, the rate is reset to the
initial value.
(To terminate the input and return to the
original state, touch the END key.)
"VIB" type