Lower Reels Time Delay

This is a solid state timer. Upon the application of power,
the load is energized and the time delay is started. After
6 seconds the load is de−energized.
1. Connect voltmeter across test load and test load to
timer. Connect 12VDC source to timer and load. Make
sure to observe polarity. After 6 seconds, there should
be no voltage across the load.
2. Disconnect timer from 12VDC source and test load.
Greensmaster 3250−D
TIMING
RESISTOR
Rev. H
Page 5 − 19
DELAY
Figure 23
+
INPUT VOLTAGE
LOAD
3
2
1
4
5
Figure 24
Electrical System (Rev. C)
TIME