General Information; Check Hydraulic System Fluid - Toro Greensmaster 3250-D 04383 Service Manual

Table of Contents

Advertisement

General Information

Operator's Manual
The Operator's Manual provides information regarding
the operation, general maintenance and maintenance
intervals for your Greensmaster 3250--D. Refer to that
publication for additional information when servicing the
machine.

Check Hydraulic System Fluid

The hydraulic system on the Greensmaster 3250--D is
designed to operate on high quality hydraulic fluid. Refer
1
to the Operator's Manual for hydraulic fluid recommen-
dations.
2
IMPORTANT: Check level of hydraulic fluid before
engine is first started and daily thereafter.
Note: If changing from one type of hydraulic fluid to
another, be certain to remove all the old fluid from the
system, as some fluids are incompatible with others.
IMPORTANT: Use only types of hydraulic fluids
Figure 1
specified in the Operator's Manual. Other fluids may
1.
Hydraulic oil cap
2.
Filler screen
cause system damage.
Checking Fluid Level
Note: A red dye additive for the hydraulic system fluid
is available in 2/3 oz bottles. One bottle is sufficient for
4 to 6 gallons of hydraulic fluid. Order Part No. 44--2500
from your Authorized Toro Distributor.
1. Position machine on a level surface. Make sure ma-
chine has cooled down so fluid is cold.
2. Remove cap from reservoir and check level of fluid.
The fluid should be up to bottom of screen in filler neck.
IMPORTANT: To prevent system contamination,
clean top of hydraulic fluid containers before punc-
turing. Make sure pour spout and funnel are clean.
3. If fluid level is low, slowly fill reservoir with appropri-
ate hydraulic fluid until level reaches bottom of screen.
DO NOT OVERFILL.
4. Install reservoir cap. Wipe up any fluid that may
have spilled.
Page 4 - - 4
Greensmaster 3250--D
Hydraulic System (Rev. I)

Advertisement