Congestion-Notify Enable; Congestion-Notify Msg - Quanta Computer T5016-LB8D Use Manual

Layer 2/3/4 managed switch
Table of Contents

Advertisement

UANTA COMPUTER INC.

10.4.5 congestion-notify enable

The user can go to the CLI Global Configuration Mode to enable handling congestion notification
message. Use the 'congestion-notify enable' global configuration command. Use the 'no
congestion-notify enable' to disable handling congestion notification message.
Syntax
congestion-notify enable
no congestion-notify enable
no - This command disables handling congestion notification message.
Default Setting
Enabled
Command Mode
Global Data-Center-Bridging Mode

10.4.6 congestion-notify msg

The user can go to the CLI Global Configuration Mode to configure the Ether Type of CNM. Use the
'congestion-notify msg ethertype <value>' global configuration command. Use the 'no congestion-notify
msg ethertype' to configure CNM Ether Type to default value
Syntax
congestion-notify msg ethertype <0-65535>
no congestion-notify msg ethertype
<0-65535> - This command sets the Ether Type value of CNM.
no - This command disables Ether Type for Congestion Notification Message (CNM).
Default Setting
0x22e7
Command Mode
Global Data-Center-Bridging Mode
_____________________________________________________________________________