Managing Lldp - Quanta Computer T5016-LB8D Use Manual

Layer 2/3/4 managed switch
Table of Contents

Advertisement

UANTA COMPUTER INC.

11.2.12 Managing LLDP

11.2.12.1 Configuring LLDP Global Configuration Page
Configurable Data
Transmit Interval - Specifies the interval in seconds to transmit LLDP frames. The range is from (1
to 32768). Default value is 30 seconds.
Transmit Delay - Specifies the transmit delay in seconds. The range is from (1 to 8192). Default
value is 2 seconds.
Hold Multiplier - Specifies the multiplier on Transmit Interval to assign TTL. The range is from (2 to
10). Default value is 4.
Re-Initialization Delay - Specifies the delay before re-initialization. The range is from (1 to 10).
Default value is 2 seconds.
Notification Interval - Specifies the interval in seconds for transmission of notifications. The range
is from (5 to 3600). Default value is 5 seconds.
Command Buttons
Submit - Send the updated screen to the switch and cause the changes to take effect on the switch
but these changes will not be retained across a power cycle unless a save is performed.
_____________________________________________________________________________