Constant Agitation; Washer Smokes, Overheats, Cycles On Motor Thermal Overload Protector, Switch Actuator Kicks In And Out - Raytheon ec2011wa3059 Service Manual

Table of Contents

Advertisement

g WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.

42. CONSTANT AGITATION

POSSIBLE CAUSE
Inoperative timer.
Shorted or incorrect wiring.
Inoperative transmission assembly.
43. WASHER SMOKES, OVERHEATS, CYCLES ON MOTOR THERMAL OVERLOAD PROTECTOR, SWITCH
ACTUATOR KICKS IN AND OUT
POSSIBLE CAUSE
Belt is tacky and does not allow proper slip.
Belt tension is too great and does not allow
proper slip.
Inoperative timer.
Motor switch functions inoperative.
Bind in water pump.
Brake pads binding.
Brake, transmission, or motor have locked
up and will not turn.
Incorrect voltage.
37989
TO CORRECT
Test timer and replace if inoperative.
Refer to appropriate wiring diagram.
Repair or replace transmission assembly.
TO CORRECT
Check belt and replace if defective.
Make sure idler spring is properly connected.
Test timer and replace if inoperative.
Check motor switch and replace if inoperative.
Replace pump.
Free binding pads, or replace pads.
Check that all these components are able to move
freely. Correct binding component.
Contact local utility company, or have a qualified
electrician check power supply.