Raytheon ec2011wa3059 Service Manual page 22

Table of Contents

Advertisement

g WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
14. MOTOR SWITCH
a. Remove two screws from bottom edge of front
panel, Figure 16.
b. Pull bottom of panel away from washer until
hold-down clips (located on top flange of
panel) disengage from slots in cabinet top.
c. Remove two screws holding motor shield to
motor, Figure 20, and remove shield.
d. Disconnect wire harness from motor switch
by pressing down on locking tab on top of
connection block and at the same time pull
connection block away from motor switch,
Figure 18.
IMPORTANT: To avoid an open circuit, DO NOT
pull on terminal block wires when removing block
from motor switch as this could damage wires or
connection crimpings. Before attaching wire
harness connection block to motor switch, make
sure all male terminals on motor switch are
straight and are capable of accepting terminals
from wire harness connection block.
37989
e. Remove screw holding motor switch to motor,
Figure 18 , and remove switch.
f. Disconnect internal motor leads from motor
switch terminals.
NOTE: Refer to Wiring Schematics, SECTION VI for
rewiring internal switch wires.
21