Agitator; Cabinet Top Assembly - Raytheon ec2011wa3059 Service Manual

Table of Contents

Advertisement

g WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.

15. AGITATOR

a. Open loading door.
b. Remove agitator by placing two agitator
hooks, No. 254P4P, under bottom edge of
agitator, Figure 21.
IMPORTANT: Hooks should be positioned 180
degrees apart and must be placed under agitator
vane for greater stability. If hooks are placed
between vanes, damage to agitator may occur.
c. Using a rocking motion (back and forth)
carefully lift agitator off drive bell.
NO. 254P4P
AGITATOR
HOOKS
AGITATOR
Figure 21

16. CABINET TOP ASSEMBLY

NOTE: When lowering cabinet top into position or
reinstalling cabinet top, pivot outer tub forward far
enough to prevent damaging (bending) out-of-
balance switch lever.
NOTE: Cabinet top is self supporting, however, a
small chain may be used for additional support,
Figure 22.
W247SE1A
22
a. Remove front panel, paragraph 10.
b. METERED MODELS:
1. Remove timer assembly, paragraph 6,
step a.
2. Remove shoulder screw and cap screw
from inside meter case.
3. Remove two cabinet top hold down screws.
4. Remove security bolt (if present) from left
rear corner of cabinet top.
c. Tape loading door closed and lift cabinet top
to a vertical position by hinging it on the rear
hold-down brackets.
CHAIN
Figure 22
W003
W252SE1A
37989