Cabinet Top Assembly Removal - Raytheon ec2011wa3059 Service Manual

Table of Contents

Advertisement

g WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.

17. CABINET TOP ASSEMBLY REMOVAL

a. Open control panel assembly, paragraph 5.
b Disconnect pressure hose from pressure
switch.
IMPORTANT: When installing pressure hose, blow
air into hose before connecting hose to switch to
remove any moisture that may have accumulated
in the hose.
c. Push base wire harness block and pressure
hose down through hole in cabinet top.
d. Tape loading door closed.
e. Open cabinet top assembly, paragraph 16.
f. Lift front of cabinet top slightly and pull
forward to disengage from rear hold-down
MIXING
VALVE
WIRE
HARNESS
DISCONNECT
BLOCKS
37989
CORNER
GUSSET
PRESSURE
GROUND
WIRE
brackets.
g. Pull top forward far enough to permit
disconnecting earth (ground) wires from top
rear corner gusset of washer cabinet,
Figure 33, disconnect wires from mixing valve
solenoids at rear of washer.
NOTE: Refer to appropriate wiring diagram when
rewiring mixing valve solenoids.
h. Carefully lift cabinet top off washer and set
on protective padding.
g WARNING
To reduce the risk of serious injury, be
careful not to damage door switch and
out-of-balance switch assembly when
removing cabinet top.
IMPORTANT: When reinstalling cabinet top and
before lowering top into position, pivot outer tub
forward far enough to prevent damaging
(bending) out-of-balance switch lever, Figure 23.
OUT-OF-BALANCE
LEVER
HOSE
Figure 23
23
W003
W342SE3A