37. NO WARM WATER

POSSIBLE CAUSE
No hot water.
No cold water.

38. WATER FILL DOES NOT STOP AT PROPER LEVEL

POSSIBLE CAUSE
Inoperative pressure switch.
Air leak in pressure hose.
Sediment on or under mixing valve diaphragm,
defective diaphragm, or armature binding in
armature guide.
Broken, weak, or missing mixing valve armature
spring.
A siphoning action started in washer will cause water
to be siphoned from washer during cycle due to
end of drain hose being lower than cabinet top of
washer. Drain hose fits tight in standpipe or drain.
Water in pressure hose.
Broken, loose, shorted, or incorrect wiring.
TO CORRECT
Refer to paragraph 35.
Refer to paragraph 36.
TO CORRECT
Test switch and replace if inoperative.
Replace hose.
Disassemble and clean mixing valve, or replace
complete valve.
Disassembly valve and replace spring, or replace.
complete valve.
Install No. 562P3 Siphon Break Kit. Provide an
air gap around drain hose and drain receptacle.
Blow air through hose to remove water.
Refer to appropriate wiring diagram.