g WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
e. CONTROL PANEL OVERLAY (Removal):
1. Remove control panel attaching screws
and lay assembly forward on protective pad
on cabinet top.
2. Loosen setscrews holding switch knobs to
switch shafts, Figure 7.
3. Remove knurled nuts holding switches to
control panel, Figure 7.
NOTE: Lockwashers must be between switches
and control panel when installing switches,
Figure 7.
4. Disconnect wires from switches and
indicator lights.
NOTE: Refer to appropriate wiring diagram when
rewiring switches and indicator lights.
5. Remove control panel overlay by peeling it
from control panel frame.
NOTE: Control panel overlay has an adhesive
backing.
37989
f. CONTROL PANEL OVERLAY (Installation):
NOTE: Before removing protective backing from
new overlay, check fit of overlay to control panel
frame. Switch holes are the locating guides.
1. Once panel overlay is fitted to the front of
control panel frame, carefully peel
protective backing from the left end of
panel overlay and press into place.
2. Remove rest of protective backing from
panel overlay and firmly press overlay into
place on control panel frame.