Meter Or Timer Case Assembly - Raytheon ec2011wa3059 Service Manual

Table of Contents

Advertisement

g WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.

7. METER OR TIMER CASE ASSEMBLY

a. METER CASE REMOVAL (Metered Models):
1. Remove two control panel attaching
screws, Figure 5, and lay assembly forward
on protective pad on cabinet top.
2. Disconnect timer harness from control hood
harness at disconnect blocks, Figure 6.
3. Remove timer assembly, paragraph 6.
4. Remove cap screw, lockwashers and nut
holding meter case to end of control hood.
5. Remove coin drawer.
6. Remove shoulder screw from inside meter
case.
NOTE: When installing meter case, shoulder
screw must be installed in outer hole, Figure 8, to
enable timer bracket to slide under screw head.
7. Remove front panel, paragraph 10.
8. Remove carriage bolts and locknuts
holding meter case to cabinet top.
9. Carefully remove meter case and gasket
from cabinet top.
b. TIMER CASE REMOVAL (Nonmetered
Models):
1. Remove timer from timer case,
paragraph 6, step c.
2. Remove two control panel attaching screws
and lay assembly forward on a protective
pad on cabinet top, Figure 5 .
3. Remove cap screw, lockwashers and nut
holding timer case to control hood,
Figure 12.
4. Remove front panel assembly,
paragraph 10.
5. Remove two cabinet top hold down screws,
Figure 16.
6. Tape loading door closed and lift cabinet
top to a vertical position.
7. Remove carriage bolts, vinyl washers,
lockwashers, and nuts holding timer case
to cabinet top.
8. Support timer case and remove screw and
fiber washer holding rear of case to cabinet
top.
ATTACHING HARDWARE
12
TIMER
CASE
SCREW
TIMER CASE
W240SE1A
Figure 12
W003
37989

Advertisement

Table of Contents
loading

Table of Contents