Snubber Pad And Isolator Assembly - Raytheon ec2011wa3059 Service Manual

Table of Contents

Advertisement

g WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.

30. SNUBBER PAD AND ISOLATOR ASSEMBLY

a. Remove outer tub, paragraph 23.
b. Locate split end of snubber pad and isolator
assembly strip and using a flat blade
screwdriver, carefully unsnap snubber pad
and isolator assembly from pivot dome area of
washer base, Figure 47.
SNUBBER PAD AND ISOLATOR ASSEMBLY
INSTALLATION:
a. Starting at elongated hole in pivot dome area
of washer base, place one end of snubber
pad and isolator assembly into elongated
hole, then snap pins on snubber pad and
isolator assembly into their respective holes
in the
base. It may require shifting snubber
pad and isolator assembly to get two ends of
strip to meet in area of elongated hole.
IMPORTANT: DO NOT APPLY ANY
LUBRICANT to surface of snubber pad and
isolator assembly or pivot dome. Any lubricant on
pivot dome or isolator will cause premature
tripping of the out-of-balance switch.
b. Clean surface of pivot dome. Then
carefully place tub module back into washer
making sure pivot dome is positioned properly
in dome recess of washer base.
ELONGATED
HOLE
NOTE: Make sure the word "FRONT" (on outer
tub) is facing toward front of washer.
c. Use No. 289P4 Spring Hook Tool and
starting with rear springs, hook seven
centering springs into lower edge of outer
tub skirt, Figure 40.
IMPORTANT: When installing centering springs,
make sure spring hook is fully seated in hole in
tub skirt, Figure 40 .
d. Connect hose to bottom of outer tub, tighten
hose clamp.
e. Reconnect idler spring to clip on motor
mounting bracket, Figure 17 .
f. Place drive belt on motor pulley, reach around
right side of motor, starting with belt on right
side of large pulley, run belt onto large pulley.
h. Route the pressure hose as shown in
Figure 48. Then route pressure hose back up
through hole in cabinet top.
i. Reconnect filler hose to tub cover, Figure 34.
NOTE: When reinstalling filler hose, white line on
hose that connects to tub cover must be aligned
with line located on top side of outer tub cover,
Figure 34. Make sure hose is in its natural
position (not kinked or twisted). If it is not, loosen
hose clamp and straighten hose.
STARTING
EDGE
Figure 47
46
ISOLATOR
STRIP
DOME AREA OF
WASHER BASE
W220SE3A
W003
37989

Advertisement