7.4.3.8 Data table control

Pulse output characteristics
R e f e r e n c e
FP0R User's Manual
This instruction performs rectangular control according to the parameters
in the specified DUT with an arbitrary number of different speeds and tar-
get values. Pulses are output from the specified channel when the control
flag for this channel is FALSE and the execution condition is TRUE.
Tool instruction: not available
F instruction: F174_PulseOutput_DataTable
x Elapsed value of pulse output
Q Execution condition
W Pulse output control flag
Pulses are output at the specified frequency until the target value is
reached. Then the frequency changes to the second frequency value
and pulse output continues until the second target value is reached, and
so forth.
Pulse output stops when the last target value is reached.
Please refer to the Control FPWIN Pro online help for details and a pro-
gramming example.
High-speed counter and pulse output
213