2JL/2JJ/2JG/2JD-1
Section
Jam code
Duplex
60
section
Duplex paper convey-
ing section 1
61
Duplex paper convey-
ing section 2
Optional
70
DP
No original feed
71
An original jam in the
original feed/conveying
section
72
An original jam in the
original feed/conveying
section 2
73
An original jam in the
original conveying sec-
tion
74
An original jam in the
original registration
section
75
An original jam in the
original registration
section
76
An original jam in the
original feed/conveying
section
78
DP cover open
1-4-6
Conditions
The duplex jam detection switch (DUJDSW) does not
turn on within specified time of the feedshift switch
(FSSW) turning on.
The duplex jam detection switch (DUJDSW) does not
turn off within specified time of the feedshift switch
(FSSW) turning off.
The registration switch (RSW) does not turn on within
specified time of the duplex jam detection switch
(DUJDSW) turning on.
The registration switch (RSW) does not turn off within
specified time of the duplex jam detection switch
(DUJDSW) turning off.
In the single-sided or double-sided original mode, pri-
mary original feed does not start.
During the secondary original feed in the single-sided
original mode, the DP timing switch (DPTSW) does
not turn on within specified time.
During the secondary original feed in the single-sided
original mode, the original feed switch (OFSW) or orig-
inal switchback switch (OSBSW) does not turn off
within specified time.
During original switchback operation in the double-
sided original mode, the original feed switch (OFSW)
or original switchback switch (OSBSW) does not turn
off within specified time.
During the secondary original feed in the single-sided
or double-sided original mode, the DP timing switch
(DPTSW) does not turn off within specified time.
The original switchback switch (OSBSW) does not
turn on within specified time.
In the single-sided original mode, the DP timing switch
(DPTSW) does not turn on within specified time.
In the double-sided original mode, the DP timing
switch (DPTSW) does not turn on within specified
time.
In the single-sided original mode, the original feed
switch (OFSW) does not turn off within specified time.
In the double-sided original mode, the original switch-
back switch (OSBSW) does not turn off within speci-
fied time.
During the secondary original feed in the single-sided
original mode, the original switchback switch
(OSBSW) does not turn on within specified time.
DP cover is open.
Specified time
25/25,32/25,
40/35 ppm
32/32 ppm
B/W/Color
3006 ms
2186 ms/
2626 ms
3006 ms
2186 ms/
2626 ms
1427 ms
1038 ms/
1247 ms
1427 ms
1038 ms/
1247 ms
-
-
1740 ms
1740 ms
5956 ms
5956 ms
4318 ms
4318 ms
3784 ms
3784 ms
2045 ms
2045 ms
1740 ms
1740 ms
907 ms
907 ms
5956 ms
5956 ms
4318 ms
4318 ms
2774 ms
2774 ms
-
-