Hour Meter

1. Park machine on a level surface, lower cutting deck,
engage parking brake and stop engine.
2. Remove control panel to gain access to hour meter
(see Control Console Disassembly in the Service and
Repairs section of Chapter 6 -- Chassis).
3. Make sure ignition switch is in the OFF position. Dis-
connect machine wire harness electrical connector from
the hour meter.
4. Connect the positive (+) terminal of a 12 VDC source
to the positive terminal of the hour meter.
5. Connect the negative (--) terminal of the voltage
source to the other terminal of the hour meter.
6. The hour meter should move 1/10 of an hour in six
(6) minutes.
7. Disconnect the voltage source from the hour meter.
8. Replace the hour meter if necessary.
9. Connect harness electrical connector to the hour
meter.
10.After testing is complete, connect machine wire har-
ness connector to the hour meter. Secure control panel
to machine with removed fasteners.