Air Conditioning Condenser Assembly - Toro Groundsmaster 360 Service Manual

Hide thumbs Also See for Groundsmaster 360:
Table of Contents

Advertisement

Air Conditioning Condenser Assembly

8
RIGHT
FRONT
1. Condenser cover
2. Lock nut (4 used)
3. Condenser fan
4. Condenser coil assembly
Removal (Fig. 5)
1. Park machine on a level surface, lower cutting deck,
stop engine, engage parking brake and remove key
from the ignition switch.
2. Remove fasteners that secure roof in place. Raise
and support roof to allow access to condenser assembly
(see Roof Assembly Removal in this section).
3. Disconnect wire harness connector from condenser
fan motor.
4. Remove button head screws (item 10) that secure
condenser fan and cover to condenser coil.
5. Remove fasteners (items 2, 6 and 8) that secure
front of condenser cover to roof. Lift condenser fan and
cover from roof.
Operator Cab
1
2
6
8
2
6
6
5
9
5. Carriage screw (2 used)
6. Flat washer (8 used)
7. Roof
8. Bushing (4 used)
10
Figure 5
6. Read the General Precautions for Removing and
Installing Air Conditioning System Components at the
beginning of the Service and Repairs section of this
chapter.
The air conditioning system is under high pres-
sure. Do not loosen any system fitting or compo-
nent until after the system has been completely
discharged by a certified A/C service technician.
7. Have refrigerant evacuated from air conditioning
system by a certified A/C service technician.
Page 8 - - 8
3
11
12
4
7
9. Mounting strap
10. Button head screw (4 used)
11. Hose (compressor to condenser)
12. Hose (condenser to drier)
CAUTION
Groundsmaster 360

Advertisement

Table of Contents
loading