Ricoh S-C4.5 Field Service Manual page 415

Machine code: d115/d116
Table of Contents

Advertisement

Address
Acceptable CED detection frequency
6805A3
lower limit (high byte)
Acceptable CED detection frequency
6805A4
lower limit (low byte)
6805A5
CED detection time
Acceptable CNG detection frequency
6805A6
upper limit (high byte)
Acceptable CNG detection frequency
6805A7
upper limit (low byte)
Acceptable CNG detection frequency
6805A8
lower limit (high byte)
Acceptable CNG detection frequency
6805A9
lower limit (low byte)
6805AA
Not used
6805AB
CNG on time
6805AC
CNG off time
Number of CNG cycles required for
6805AD
detection
6805AE
Not used
Acceptable AI short protocol tone
6805AF
(800Hz) detection frequency upper limit
(high byte)
Acceptable AI short protocol tone
6805B0
(800Hz) detection frequency upper limit
(low byte)
Acceptable AI short protocol tone
6805B1
(800Hz) detection frequency lower limit
(high byte)
Acceptable AI short protocol tone
6805B2
(800Hz) detection frequency lower limit
(low byte)
Function
Unit
If both addresses contain FF
BCD (Hz)
(H), tone detection is
disabled.
20 ms ± 20 ms Factory setting: 200 ms
If both addresses contain FF
BCD (Hz)
(H), tone detection is
disabled.
If both addresses contain FF
BCD (Hz)
(H), tone detection is
disabled.
-
Do not change the setting.
20 ms
Factory setting: 500 ms
20 ms
Factory setting: 3000 ms
The data is coded in the same
-
way as address 680533.
-
Do not change the settings.
If both addresses contain FF
Hz (BCD)
(H), tone detection is
disabled.
If both addresses contain FF
Hz(BCD)
(H), tone detection is
disabled.
NCU Parameters
Remarks
219
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D115D116

Table of Contents