Ricoh S-C4.5 Field Service Manual page 166

Machine code: d115/d116
Table of Contents

Advertisement

6. Troubleshooting
B
B
B
6
B
B
B
164
[00FF]: Detailed error code
Cache access error in the CPU
[0601, 0602, 0605, 0606, 0607, 0609]: Detailed error code
Exceptional command does not
operate even though it is executed on
purpose.
[060A-060E]: Detailed error code
Cut-in command does not operate
when it is executed.
[0610]: Detailed error code
Timer cut-in does not operate even
though it is set.
[0612]: Detailed error code
Cut-in in ASIC occurs.
[06FF]: Detailed error code
The pipeline clock frequency rate is
different from the prescribed value.
• Defective CPU
• Defective local bus
1. Turn the main power switch off and on.
2. Reinstall the system program.
3. Replace the controller board.
• Defective CPU devices
1. Replace the controller board.
• Defective CPU devices
• Defective ASIC devices
1. Replace the controller board.
• Defective CPU devices
1. Replace the controller board.
• Defective ASIC
• Defective devices in which ASIC
detects cut-in.
1. Replace the controller board.
• Defective CPU devices
• Mode bit data error, which is used for
initializing CPU.
1. Replace the controller board.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D115D116

Table of Contents